Gebwell-T2-heat-pump

T² heat pump

Cost-efficient and reliable solution for more demanding needs.

Read More
Request an Offer

Description

T² heat pump is to be connected to a separate accumulator and designed to heat large detached houses, apartment buildings, industrial facilities and other buildings requiring lots of heating. T² heat pump can also be installed in renovated buildings since the quiet and reliable compressors easily produce +65°C output water.

The latest compressor technique, durable components and advanced automation ensure energy-efficient and reliable heating and long lifetime. Hot domestic water is produced efficiently in two-part hybrid accumulator. By connecting two accumulators sufficient hot domestic water production can be ensured in the most demanding properties.

By combining several T² heat pumps in cascade sufficient heating capacity for large terraced houses and apartment buildings. T² heat pump system can be integrated with a diverse additional heating sources like solar, oil or wood heating.

With extension modules the versatile controller can be further supplemented for example to control three heating circuits and possible other additional heating sources. Installation-friendly design ensures profitable and fast installation.

 

  • High efficiency
  • Scroll-compressor
  • Intelligent cascade control
  • Versatile controller
  • Manufactured in Finland
  • Energy class*

Technical Information

Technical information

Gebwell T2 T206 T208 T210 T213 T216 T220 T226 T232
GTIN (64158..) 5361924 5361925 5361926 5361927 5361928 5361929 5361930 5361942
Power values:
Heating output (0°/35°C and 0°/55°C) kW 5,3 / 4,9 7,4 / 6,8 9,4 / 8,5 13,3 / 12,2 15,9 / 14,6 22,5 / 20,3 30,5 / 27,3 34,6 / 30,9
Cooling capacity (0°/35°C and 0°/55°C) kW 4,2 / 3,2 5,8 / 4,4 7,4 / 5,6 10,5 / 8,1 12,6 / 9,6 17,5 / 12,8 24,0 / 17,6 27,4 / 20,1
Input power (0°/35°C and 0°/55°C) kW 1,1 / 1,7 1,6 / 2,4 2,0 / 2,9 2,8 / 4,1 3,3 / 5,0 5,0 / 7,5 6,5 / 9,7 7,2 / 10,8
COP (0°/35 °C ja 0°/55 °C) 4,8 / 2,9 4,6 / 2,8 4,7 / 2,9 4,8 / 3,0 4,8 / 2,9 4,5 / 2,7 4,7 / 2,8 4,8 / 2,9
SCOP (0°/35 °C ja 0°/55 °C) 5,2 / 4,3 5,4 / 4,6 5,5 / 4,6 5,4 / 4,5 5,3 / 4,6 4,7 / 4,0 4,9 / 4,1 5,0 / 4,2
Power values stated at temperatures 0°/35°C and 0°/55°C, SFS-EN 14511
System’s energy efficiency class, intermediate climate, underfloor heating A+++
Heat collecting liquid Denaturated ethanol 30 p-%
Heat collecting liquid nomina flow l/s 0,3 0,41 0,5 0,6 0,74 0,98 1,23 1,48
Maximum allowed external pressure loss at the heat collecting loop nominalflow kPa 61 48 90 74 75 81 70 100
bar 6 /6 6 /6 6 /6 6 /6 6 /6 6 /6 6 /6 6 /6
Heating water maximum output temperature °C 65 65 65 65 65 68 68 68
Operational temperature, collecting loop °C -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20
Compressor Scroll
Compressor soft starter Yes
Built-in heating pump Yes
Source pump Yes Yes Yes Yes Yes No No No
Electrical connection 400 VAC. 50 Hz. 3-phase
Sulakkeet (Additional electrical resistor (accessory) can be connected) kW 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9
Fuses A 3x10 3x10 3x10 3x16 3x16 3x20 3x25 3x32
Contains fluorinated greenhouse gases Yes
Hermetically sealed Yes
Refrigerant R407C R407C R407C R407C R407C R410A R410A R410A
GWP (global warming potential) 1774 1774 1774 1774 1774 2088 2088 2088
Refrigerant amount kg 1,8 1,8 1,8 2,2 2,5 3,8 3,4 3,4
CO2 equivalence - tonnes CO2 e ton CO2 e 3,193 3,193 3,193 3,903 4,435 7,934 7,099 7,099
Sound power level dB 38,5 38,5 40 40 42 42 42 43,5
Dimensions
Outside dimensions (depth x width x height) mm 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200*
Weight kg 168 172 180 195 205 230 230 225

Downloads

T2 Heat Pump techical leaflet 604 KB Download
T2 Heat Pump Installation Manual 5 MB Download
Gebwell UI400 Interface quick guide 1 MB Download

T² heat pump is to be connected to a separate accumulator and designed to heat large detached houses, apartment buildings, industrial facilities and other buildings requiring lots of heating. T² heat pump can also be installed in renovated buildings since the quiet and reliable compressors easily produce +65°C output water.

The latest compressor technique, durable components and advanced automation ensure energy-efficient and reliable heating and long lifetime. Hot domestic water is produced efficiently in two-part hybrid accumulator. By connecting two accumulators sufficient hot domestic water production can be ensured in the most demanding properties.

By combining several T² heat pumps in cascade sufficient heating capacity for large terraced houses and apartment buildings. T² heat pump system can be integrated with a diverse additional heating sources like solar, oil or wood heating.

With extension modules the versatile controller can be further supplemented for example to control three heating circuits and possible other additional heating sources. Installation-friendly design ensures profitable and fast installation.

 

  • High efficiency
  • Scroll-compressor
  • Intelligent cascade control
  • Versatile controller
  • Manufactured in Finland
  • Energy class*

Technical information

Gebwell T2 T206 T208 T210 T213 T216 T220 T226 T232
GTIN (64158..) 5361924 5361925 5361926 5361927 5361928 5361929 5361930 5361942
Power values:
Heating output (0°/35°C and 0°/55°C) kW 5,3 / 4,9 7,4 / 6,8 9,4 / 8,5 13,3 / 12,2 15,9 / 14,6 22,5 / 20,3 30,5 / 27,3 34,6 / 30,9
Cooling capacity (0°/35°C and 0°/55°C) kW 4,2 / 3,2 5,8 / 4,4 7,4 / 5,6 10,5 / 8,1 12,6 / 9,6 17,5 / 12,8 24,0 / 17,6 27,4 / 20,1
Input power (0°/35°C and 0°/55°C) kW 1,1 / 1,7 1,6 / 2,4 2,0 / 2,9 2,8 / 4,1 3,3 / 5,0 5,0 / 7,5 6,5 / 9,7 7,2 / 10,8
COP (0°/35 °C ja 0°/55 °C) 4,8 / 2,9 4,6 / 2,8 4,7 / 2,9 4,8 / 3,0 4,8 / 2,9 4,5 / 2,7 4,7 / 2,8 4,8 / 2,9
SCOP (0°/35 °C ja 0°/55 °C) 5,2 / 4,3 5,4 / 4,6 5,5 / 4,6 5,4 / 4,5 5,3 / 4,6 4,7 / 4,0 4,9 / 4,1 5,0 / 4,2
Power values stated at temperatures 0°/35°C and 0°/55°C, SFS-EN 14511
System’s energy efficiency class, intermediate climate, underfloor heating A+++
Heat collecting liquid Denaturated ethanol 30 p-%
Heat collecting liquid nomina flow l/s 0,3 0,41 0,5 0,6 0,74 0,98 1,23 1,48
Maximum allowed external pressure loss at the heat collecting loop nominalflow kPa 61 48 90 74 75 81 70 100
bar 6 /6 6 /6 6 /6 6 /6 6 /6 6 /6 6 /6 6 /6
Heating water maximum output temperature °C 65 65 65 65 65 68 68 68
Operational temperature, collecting loop °C -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20 -5 ... +20
Compressor Scroll
Compressor soft starter Yes
Built-in heating pump Yes
Source pump Yes Yes Yes Yes Yes No No No
Electrical connection 400 VAC. 50 Hz. 3-phase
Sulakkeet (Additional electrical resistor (accessory) can be connected) kW 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9 3 /6 /9
Fuses A 3x10 3x10 3x10 3x16 3x16 3x20 3x25 3x32
Contains fluorinated greenhouse gases Yes
Hermetically sealed Yes
Refrigerant R407C R407C R407C R407C R407C R410A R410A R410A
GWP (global warming potential) 1774 1774 1774 1774 1774 2088 2088 2088
Refrigerant amount kg 1,8 1,8 1,8 2,2 2,5 3,8 3,4 3,4
CO2 equivalence - tonnes CO2 e ton CO2 e 3,193 3,193 3,193 3,903 4,435 7,934 7,099 7,099
Sound power level dB 38,5 38,5 40 40 42 42 42 43,5
Dimensions
Outside dimensions (depth x width x height) mm 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200* 775 x 600 x 1200*
Weight kg 168 172 180 195 205 230 230 225