Taurus-EVIC-
New

Taurus EVIC heat pump

A compact tandem heat pump with two compressors for heating large properties.

Read More
Request an Offer

Description

Taurus EVIC is a tandem heat pump with two EVI compressors and a controller with IoT features.

Taurus EVIC Heat Pump is an excellent choice for heating large properties. The Taurus EVIC heat pump offers the same excellent technical features as our previous Taurus EVI model. The EVI heat pump is equipped with economizer, which improvex the refrigerant circuit’s heating output and efficiency, especially when the heating circuit operates at high temperatures.

Data from the IoT controller that is stored in the cloud service are used in system development. The data stored in the cloud service enables adjusting heating based on weather forecasts, and learning the thermal capacity and the heating/cooling behaviour of a certain property, for example. Furthermore, the cloud service enables remote updating of the controller software and monitoring and controlling the system online using a browser-based Gebwell Smart Control Hub.

The new Taurus EVIC heat pump is easier to haul and install. The EVIC is smaller and lighter than the EVI heat pump, so it is easier to haul and install. Fixed connection couplings also improve installation. Thanks to its small size, the Taurus EVIC can fit into lower installation spaces than the EVI model.

Taurus EVIC heat pump comes in two capacities Taurus EVIC 80 and Taurus EVIC 110.

  • Made in Finland
  • Heating water maximum output temperature up to 0 / +65 degree celsius
  • Top efficiency with partial loads
  • Two power stages
  • Controller with IoT features
  • De-superheater exchanger

Technical specifications

  • Two power stages 80 EVIC: 37 kW and 74 kW 110 EVIC: 48 kW and 96 kW
  • Operational temperature, collector  -5 – +20 °C
  • Refrigerant R410a, amount 10,4 kg
  • Built-in source and heating pumps
  • Recommended fuse size 3 x 80 A
  • External dimensions (L x W x H) 1150 x 760 x 1550 mm, weight 680 kg

Technical Information

Taurus 80 EVIC Taurus 110 EVIC
Power values (according to EN 14511)
Heating output (0°/35° and 0°/55°) kW 71.4 and 74.3 93.6 and 97.8
Cooling output (0°/35° and 0°/55°) kW 56.4 and 50.0 74.1 and 65.2
Electrical power (0°/35° 0°/55°) kW 16.1 and 25.5 20.9 and 32.6
Rated heating output (0°/35° 0°/55°) kW 71.4 and 74.3 93.6 and 97.8
Rated electrical power (0°/35° and 0°/55°) kW 16.1 and 25.5 20.9 and 32.6
COP (0°/35° and 0°/55°) 4.4 and 2.9 4.5 and 3.0
SCOP (0°/35° and 0°/55°, according to EN 14825) 5.2 and 4.4 5.2 and 4.5
Heating circuit rated flow l/s 2.4 3.2
Brine Denaturated ethanol 25-30 p-% Denaturated ethanol 25-30 p-%
Heating water maximum output temperature °C 0/+65 0/+65
Operational temperature, collector °C -5…+20 -5…+20
Built-in heating pump yes, with frequency converter yes, with frequency converter
Built-in source pump yes, with frequency converter yes, with frequency converter
Compressor Scroll (EVI) Scroll (EVI)
Compressors pcs 2 2
Contains fluorinated greenhouse gases yes yes
Hermetically sealed yes yes
Refrigerant R410A R410A
GWP (global warming potential) 2'088 2'088
Refrigerant amount kg 10.4 10.4
CO2 equivalence ton CO2 e 21,715 21,715
Sound effect level dB 52-58 52-58
Dimensions
Depth x widht x height mm 1150 x 760 x 1550 1150 x 760 x 1550
Weight kg 680 680

Downloads

Taurus EVIC heat pump technical leaflet 166 KB Download
Gebwell CLI Controller menu structure 663 KB Download

Taurus EVIC is a tandem heat pump with two EVI compressors and a controller with IoT features.

Taurus EVIC Heat Pump is an excellent choice for heating large properties. The Taurus EVIC heat pump offers the same excellent technical features as our previous Taurus EVI model. The EVI heat pump is equipped with economizer, which improvex the refrigerant circuit’s heating output and efficiency, especially when the heating circuit operates at high temperatures.

Data from the IoT controller that is stored in the cloud service are used in system development. The data stored in the cloud service enables adjusting heating based on weather forecasts, and learning the thermal capacity and the heating/cooling behaviour of a certain property, for example. Furthermore, the cloud service enables remote updating of the controller software and monitoring and controlling the system online using a browser-based Gebwell Smart Control Hub.

The new Taurus EVIC heat pump is easier to haul and install. The EVIC is smaller and lighter than the EVI heat pump, so it is easier to haul and install. Fixed connection couplings also improve installation. Thanks to its small size, the Taurus EVIC can fit into lower installation spaces than the EVI model.

Taurus EVIC heat pump comes in two capacities Taurus EVIC 80 and Taurus EVIC 110.

  • Made in Finland
  • Heating water maximum output temperature up to 0 / +65 degree celsius
  • Top efficiency with partial loads
  • Two power stages
  • Controller with IoT features
  • De-superheater exchanger

Technical specifications

  • Two power stages 80 EVIC: 37 kW and 74 kW 110 EVIC: 48 kW and 96 kW
  • Operational temperature, collector  -5 – +20 °C
  • Refrigerant R410a, amount 10,4 kg
  • Built-in source and heating pumps
  • Recommended fuse size 3 x 80 A
  • External dimensions (L x W x H) 1150 x 760 x 1550 mm, weight 680 kg
Taurus 80 EVIC Taurus 110 EVIC
Power values (according to EN 14511)
Heating output (0°/35° and 0°/55°) kW 71.4 and 74.3 93.6 and 97.8
Cooling output (0°/35° and 0°/55°) kW 56.4 and 50.0 74.1 and 65.2
Electrical power (0°/35° 0°/55°) kW 16.1 and 25.5 20.9 and 32.6
Rated heating output (0°/35° 0°/55°) kW 71.4 and 74.3 93.6 and 97.8
Rated electrical power (0°/35° and 0°/55°) kW 16.1 and 25.5 20.9 and 32.6
COP (0°/35° and 0°/55°) 4.4 and 2.9 4.5 and 3.0
SCOP (0°/35° and 0°/55°, according to EN 14825) 5.2 and 4.4 5.2 and 4.5
Heating circuit rated flow l/s 2.4 3.2
Brine Denaturated ethanol 25-30 p-% Denaturated ethanol 25-30 p-%
Heating water maximum output temperature °C 0/+65 0/+65
Operational temperature, collector °C -5…+20 -5…+20
Built-in heating pump yes, with frequency converter yes, with frequency converter
Built-in source pump yes, with frequency converter yes, with frequency converter
Compressor Scroll (EVI) Scroll (EVI)
Compressors pcs 2 2
Contains fluorinated greenhouse gases yes yes
Hermetically sealed yes yes
Refrigerant R410A R410A
GWP (global warming potential) 2'088 2'088
Refrigerant amount kg 10.4 10.4
CO2 equivalence ton CO2 e 21,715 21,715
Sound effect level dB 52-58 52-58
Dimensions
Depth x widht x height mm 1150 x 760 x 1550 1150 x 760 x 1550
Weight kg 680 680
Taurus EVIC heat pump technical leaflet 166 KB Download
Gebwell CLI Controller menu structure 663 KB Download