LSRSi-2-4

Control group for heating

By connecting two control groups to heat pump, you can heat damp spaces all-year round regardless of heating needs of other rooms, for example.

Read More
Request an Offer

Description

With heating control group the adjusting of heating network is easy and installation time of heat pump signicantly shorter.

Connecting the control group to the heating network is easy and effortless. By connecting two control groups to heat pump, you can heat damp spaces all-year round regardless of heating needs of other rooms, for example.

  • Shortens installation time
  • Facilitates adjusting of heating circuit
  • Easy to use

Technical Information

Technical information

Heating control group GTIN 64158.. Feasibility, heat pump Feasibility, radiator heating, kW Feasibility, floor heating, kW Valve KVS value Circulation pump
Heating control group Aries 53626637 Aries 1,5-7,5 1,5-7,5 4 Grundfos UPM3 Auto 15-70
LSR Si KV4 Heating control group P1-23 L1-6 53626644 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 1-23 1-6 4 Grundfos UPM3 Auto 15-70
LSR Si KV6.3 Heating control group P23-45 L6-14 53626651 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 23-45 6-14 6.3 Grundfos Magna 3 25-100
LSR Si KV10 Heating control group P45-70 L14-22 53626668 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 45-70 14-22 10 Grundfos Magna 3 25-100
LSR Si KV16 Heating control group P70-110 L22-36 53626675 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 70-110 22-36 16 Grundfos Magna 3 25-100
LSR Si KV25 Heating control group P110-180 L36-56 53626682 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 110-180 36-56 25 Grundfos Magna 3 40-120
LSR Si KV40 Heating control group P180-240 L56-90 53626699 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 180-240 56-90 40 Grundfos Magna 3 40-120
Pump heating group 0,6 l/s - 3m 5361988 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 15-23 1-6 - Grundfos UPM3 Auto 15-70
Pump heating group 1,7 /s - 5,5m 5361989 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 23-110 6-36 - Grundfos Magna 3 25-100
Pump heating group 3,3 l/s - 6m 5361990 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 110-240 36-90 - Grundfos Magna 3 40-120

Downloads

Heating Control Group installation manual Download

With heating control group the adjusting of heating network is easy and installation time of heat pump signicantly shorter.

Connecting the control group to the heating network is easy and effortless. By connecting two control groups to heat pump, you can heat damp spaces all-year round regardless of heating needs of other rooms, for example.

  • Shortens installation time
  • Facilitates adjusting of heating circuit
  • Easy to use

Technical information

Heating control group GTIN 64158.. Feasibility, heat pump Feasibility, radiator heating, kW Feasibility, floor heating, kW Valve KVS value Circulation pump
Heating control group Aries 53626637 Aries 1,5-7,5 1,5-7,5 4 Grundfos UPM3 Auto 15-70
LSR Si KV4 Heating control group P1-23 L1-6 53626644 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 1-23 1-6 4 Grundfos UPM3 Auto 15-70
LSR Si KV6.3 Heating control group P23-45 L6-14 53626651 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 23-45 6-14 6.3 Grundfos Magna 3 25-100
LSR Si KV10 Heating control group P45-70 L14-22 53626668 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 45-70 14-22 10 Grundfos Magna 3 25-100
LSR Si KV16 Heating control group P70-110 L22-36 53626675 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 70-110 22-36 16 Grundfos Magna 3 25-100
LSR Si KV25 Heating control group P110-180 L36-56 53626682 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 110-180 36-56 25 Grundfos Magna 3 40-120
LSR Si KV40 Heating control group P180-240 L56-90 53626699 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 180-240 56-90 40 Grundfos Magna 3 40-120
Pump heating group 0,6 l/s - 3m 5361988 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 15-23 1-6 - Grundfos UPM3 Auto 15-70
Pump heating group 1,7 /s - 5,5m 5361989 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 23-110 6-36 - Grundfos Magna 3 25-100
Pump heating group 3,3 l/s - 6m 5361990 T3 Inverter, Gemini Inverter, Taurus Inverter PRO and Taurus EVI/EVIC 110-240 36-90 - Grundfos Magna 3 40-120
Heating Control Group installation manual Download